Muffle furnace laboratory work application method

CEM patented quartz fiber crucible

1. Circulating airflow improves oxidation rate

2. Volume capacity: 20, 50, 100ml

3. Strong and resistant to breakage

4. Reusable

5.30 seconds to cool down to room temperature

6. Sample encryption closed lid

1. The heating speed is fast and easy to control: the maximum temperature can reach 1200 ℃, 16 steps of 1-8 steps gradient heating.

2. Direct ashing without carbonization: The carbonization process of evaporating water and burning to remove organic matter before putting the sample into the muffle furnace is omitted.

3. Short ashing time: most samples can be completely ashed within 10 minutes, while ordinary muffle furnaces require several hours or even tens of hours.

4. Instant cooling: it takes only tens of seconds to cool after the ashing is completed, the traditional method takes an hour or even longer.

5. Compatible with all kinds of traditional crucibles, and also has CEM patented quartz fiber crucible, making ashing faster.

6. Accurate and safe: The internal safety locking mechanism can automatically stop the operation of the instrument when an unexpected situation occurs.

CEM patented quartz fiber crucible

1. Circulating airflow improves oxidation rate

2. Volume capacity: 20, 50, 100ml

3. Strong and resistant to breakage

4. Reusable

5.60 seconds to cool to room temperature

6. Sample encryption closed lid

6 How to use the box resistance furnace

6.1 The electric furnace must be placed on a flat workbench indoors. The temperature controller should avoid vibration, and should not be placed too close to the electric furnace to prevent overheating that prevents the electronic components from working properly. When moving the thermostat, set the power switch to "OFF".

6.2 Adjust the setting pointer of the temperature indicator to the required working temperature, turn on the power, press the power switch to energize the electric furnace, then the ammeter has a reading, the pointer of the temperature indicator gradually rises, indicating that the electric furnace and the thermostat are both normal work.

6.3 When the electric furnace is used for the first time or re-used after long-term shutdown, it must be oven dried: open the door at 20 ~ 200 ℃ for 4h, close it at 200 ~ 600 ℃ for 4h.

6.4 When the electric furnace is used, the furnace temperature shall not exceed the rated temperature, so as not to damage the heating element.

6.5 It is forbidden to directly inject various liquids and molten metals into the furnace, and keep the furnace clean.

6.6 Regularly check whether the connection parts of the conductive system of the electric furnace and the temperature controller are in good contact. When a fault occurs, the power should be cut off immediately and inspected by professional maintenance personnel.

When using for the first time or after long-term use, the oven should be used first, the temperature is 200 ~ 600 ℃, and the time is about 4 hours.

~ The furnace temperature must not exceed the maximum furnace temperature during use, and do not work above the rated temperature for a long time.

~ Working environment requires no flammable and flammable materials and corrosive gases.

~ In order to ensure safe use, a ground wire must be added and well grounded.

~ The furnace door should be closed and opened gently to prevent damage to the machine parts.

~ When placing samples in the furnace, first turn off the power and gently handle it to ensure safety and avoid damage to the furnace.

~ In order to prolong the service life of the product and ensure safety, the samples should be taken out of the furnace chamber in time after the equipment is used, and the heating and power should be turned off.

The Tear-Off Cap For Oral Liquids is divided into two types, i.e.: top‐pull type and side‐pull type.

Involving in multiple working procedures, such as the: punch forming of aluminum cap, injection molding of Plastic Cap, press / cutting indentation, surface treatment, cleaning, riveting, inspection, inner and outer packing. The size and color could be satisfied on the request of user.

Tear-off Cap For Oral Liquid

Tear-Off Cap For Oral Liquids,Tear Off Cap,Aluminium Tear Off Cap,Glass Bottle Of Tear-Off Cap

YANGZHONG HONGYUN BOTTLE CAPS MAKING FACTORY , https://www.hongyunyz.com